Fluke 810 Vibration Tester
|
|
Analyzes common equipment, like motors, fans and pumps, and determines the root cause and location of mechanical failure.
Types of Common Equipment which can be Analyzed:
Motors
Fans and blowers
Belts and chain drives
Gearboxes
Pumps
Compressors
Spindles
Detect the root cause of mechanical failure:
Bearing problems
Misalignment
Unbalance
Looseness
Intuitive user interface is multilingual and icon-based
Tri-axial TEDS accelerometer reduces measurement... |
Vibration Testers
|
|
|
|
Fluke VT02 Visual Infrared (IR) Thermometer 10°C to +250°C (14°F to 482°F) Temp. Range, 2°C Accuracy
|
|
-10°C to +250°C (14°F to 482°F) Temperature Measurement Range
2°C or 2% (at 25 °C nominal, whichever is greater) Accuracy
Detect issues instantaneously with digital and thermal blended images
Pinpoint hot and cold spots with temperature markers
Perform inspections up to 30 times faster than traditional infrared thermometers
Document and communicate problems efficiently with SmartView reporting software
|
Visual Thermometer
|
|
|
|
Fluke VT04 14 °F to 482 °F Visual IR Thermometer with PyroBlend Plus optic
|
|
Detect issues instantly with built-in digital camera
No training required; Fully automatic with built-in intelligence
True pocket size design
Breakthrough affordability: Half the cost of infrared cameras that require training and software
Exclusive thermal heat map blending overlay
Blend digital and thermal images to instantly show the exact location of the issue
Blend between 0 %, 25 %, 50 %, 75 %, and full thermal with one button
Powerful resolution with PyroBlend Plus... |
Visual Thermometer
|
|
|
|
Fluke 281, 282, & 284 Arbitrary Waveform Generators
|
|
Choice of 1, 2 and 4 independent or linked channels
40 MS/s max. sampling speed
16 MHz function generator
10 MHz pulse generator
Pulse train pattern generator
Arbitrary waveforms of up to 65 k points
Powerful modulation capabilities
Built-in trigger generators
Waveform Manager Plus for Windows® software
Multiple standard waveforms recalled from internal memory
RS-232 and GPIB interfaces
|
Waveform Generators
|
|
|
|
Fluke 291, 292, & 294 Arbitrary Waveform Generators
|
|
1 (Fluke 291), 2 (Fluke 292) or 4 (Fluke 294) independent arbitrary channels
Additional DC to 50MHz fixed amplitude sine and squarewave outputs on 2- and 4-channel instruments
100 MS/s 12-bit arbitrary waveform capability
1 M point waveform memory
40MHz function generator capabilities using DDS (50 MHz for square waves)
Output level 2.5 mV to 10 V p-p into 50 Ω with 12 bit vertical resolution
10 ns pulse pattern generator
Waveform sequencing with up to 1024 segments
Unlimited... |
Waveform Generators
|
|
|
|
Fluke CNX I3000 Wireless iFlex AC Current Module and accessories
|
|
LCD w/backlight 3½ digits
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Log rate/interval 1 sec minimum/adjustable by PC or front panel
EMC EN 61326-1:2006
|
Wireless Multimeters
|
|
|
|
Fluke CNX V3000 AC Wireless Voltage Module
|
|
True-RMS AC voltage measurements to 1000V
LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
EMC EN 61326-1:2006
|
Wireless Multimeters
|
|
|
|
Fluke CNX A3000 AC Current Clamp Module
|
|
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
EMC EN 61326-1:2006
Crest factor (50 Hz/60 Hz) 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 2
|
Wireless Multimeters
|
|
|
|
Fluke CNX T3000 K-Type Temperature Module and accessories
|
|
LCD w/backlight 3 ½ digits
Log rate/interval 1 sec minimum/adjustable by PC
EMC EN 61326-1:2006
|
Wireless Multimeters
|
|
|
|
Fluke CNX i3000 KIT Wireless Multimeter, iFlex Clamp Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX V3000 Kit Wireless Multimeter, AC Wireless Voltage Voltage Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX A3000 KIT Multimeter, AC Current Clamp Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke FLK-CNX T3000 KIT Wireless Multimeter, Temperature Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX 3000 IND Wireless Multimeter, 3 iFlex Clamp Modules, 1 Voltage Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX 3000 HVAC Wireless Multimeter, AC Current Clamp Module, Temperature Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX 3000 GM Wireless Multimeter, iFlex Clamp Module, Voltage Module and accessories
|
|
Save money and time by taking multiple measurements simultaneously
Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
Capture readings at different intervals, with user-set recording intervals from one second to one hour
Choose the module(s) that work best for your applications
Identify up to 10 placed modules with meter or PC and choose only the ones you need
View up to 10 live readings at once on a PC to get a... |
Wireless Multimeters
|
|
|
|
Fluke CNX 3000 Wireless Testers
|
|
Your tools - connected. Take readings quicker. Solve problems faster. Fluke CNX 3000 wireless test tools work together to help you troubleshoot faster. With the CNX team, measurements are:
Remote
Simultaneous
Recordable
The Fluke CNX Wireless System is a troubleshooting system with a digital multimeter as the core device. The DMM receives and displays up to three voltage, amperage and/or temperature readings from multiple wireless modules placed in a variety of locations up to 20... |
Wireless Multimeters
|
|
|
|
Fluke 90i-610s 1A to 600A AC/DC Current Probe
|
|
Current Range: 1 to 600 A DC or AC Peak
Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A)
Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A
Frequency Range: 40 Hz to 400 Hz
Working Voltage: 600 V AC rms
Maximum Conductor Diameter: 34 mm (1.34 inch)
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
|
Automotive Accessories
|
|
|
|
Fluke BP880 BNC to Female Double Stacking Banana Plug
|
|
Allows for hands-free testing in controlled voltage environments 500 VRMS maximum
Banana plug is nickel-plated, beryllium copper for low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50 °C (+122 °F) maximum
|
Automotive Accessories
|
|
|
|
Fluke BP881 BNC to Male Double Stacking Banana Plug
|
|
Allows for hands-free testing in controlled voltage environments 500 VRMS maximum
Banana plug is nickel-plated, beryllium copper for low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50 °C (+122 °F) maximum
|
Automotive Accessories
|
|