Features:
* 50MHz Bandwidth, Dual Channel
* Delayed Sweep (GOS-653G)
* Built-In Delay Line (GOS-653G)
* TV Synchronization
* CH1 Output
* Z-Axis Modulation Input
* ALT Triggering Function
* Hold Off Function
* Trigger Level Lock Function
Description:
The 50MHz GOS-653G/652G Series is an example of classic analog oscilloscope design. The GOS-653G /652G cover a broad range of industry applications, such as product design, assembly lines, repair & servicing, and educational purposes for EE laboratories and class experiments. Coupled with various trigger functions (Auto, Norm, TV), complex waveforms can be easily triggered for use in diverse applications. The ALT Trigger function enables users to observe signals from dual channels simultaneously. The Hold Off function helps stabilize sophisticated signals within repetitive frequencies or periods. Delayed sweep magnification (GOS-653G) can display and zoom in waveforms at the same time. For classic design and operation applicable to a wide range of applications, the GOS-653G/652G Series offers extra value.
Specification;
CRT | |
Type | 6-inch rectangular type with internal graticule 0%, 10%, 90% and 100% markers. 8 x 10 div (1div=1cm) |
Accelerating Potential | 12kV |
Illumination | Continuously adjustable |
Z-axis Input |
Input Impedance: Approx. 5kΩ Sensitivity:Above 3Vp-p Bandwidth:DC ~ 5MHz |
VERTICAL SYSTEM | |
Sensitivity | 5mV ~ 5V/div±3%,1mV ~ 2mV/div±5% |
Bandwidth | DC ~ 50MHz DC ~ 15MHz at 1 ~ 2mV/div |
Rise Time | 7ns (23.3ns for 1 ~ 2mV/div) |
Signal Delay |
leading edge can be monitored (GOS-653G only) |
Input Impedance | Approx. 1MΩ |
Input Coupling | AC, DC, GND |
Vertical Mode |
CH1, CH2, DUAL, ADD, CH2 INV (Dual automatic switching ALT and CHOP) |
HORIZONTAL SYSTEM | |
A(main) Sweep Time | 0.1μs ~ 0.5s/div ±3% 100ns ~ 50ms/div ±5% (x 10 MAG) 10ns ~ 50ns ±8% (x 10 MAG) |
B(delay) Sweep Time | 0.1μs ~ 0.5ms/div ±3% 100ns ~ 50μs/div ±5% (x 10 MAG) 10ns ~ 50ns/div ±8% (x 10 MAG) |
Delay Time | 1μs ~ 5ms/div ±5% (GOS-653G only) |
Delay Time Jitter | Better than 1:10000 (GOS-653G only) |
TRIGGER | |
Trigger Mode | AUTO, NORM, SINGLE |
Trigger Source | CH1, CH2, ALT, LINE, EXT |
Trigger Coupling | AC, DC, HF REJ, TV |
Trigger Slope | "+" or "-" |
X-Y OPERATION | |
Sensitivity | 5mV ~ 5V/div±4% |
X-axis Bandwidth | DC ~ 2MHz |
Phase Error | 3° or less from DC ~ 100kHz |
OUTPUT SIGNAL |
|
Ch1 Signal Output | Voltage: approx. 50mV/div into 50Ω |
Calibrator Output | 1kHz Square wave, 2Vpp±2% |
POWER SOURCE | |
AC 100V/ 120V/ 220V/ 230V ±10%, 50Hz/ 60Hz | |
DIMENSIONS & WEIGHT | |
310(W) x 150(H) x 455(D) mm; Approx. 8.2kg |
Accessories:
User manual x 1, Power cord x 1
GTP-060A-4: 60MHz (10:1/1:1) Switchable Passive Probe (one per channel)
Optional Accessories
GTL-110 Test lead, BNC-BNC heads
GTC-001 Instrument cart, 450(W) x 430(D)mm (120V input socket)
GTC-002 Instrument cart, 330(W) x 430(D)mm (120V input socket)
Ordering Information:
GOS-653G 50MHz, 2 channel analog oscilloscope with Delayed Sweep
GOS-652G 50MHz, 2 channel analog oscilloscope