GAS DNA SS-100 Two color Non-Contact Fixed Pyrometer
|
|
SS-100 two color(Si/Si) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 800 ℃ to maximum 2400℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. |
Fixed Infrared thermometer
|
|
|
GAS DNA 2IGA -100 Two color Non-Contact Fixed Pyrometer
|
|
2IGA-100 two color(InGaAs/InGaAs) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 400 ℃ to maximum 1200℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. |
Fixed Infrared thermometer
|
|
|
GAS DNA IR-Compact Non-Contact subminiature Fixed Infrared Thermometer
|
|
IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) and RS-485 communication signal output. It can measure from -60℃ to maximum 350℃ in the distance of 8:1 D:S (Distance to Spot) Emissivity is 0.10 ~ 0.99 adjustable. IR-Compact can monitor the temperature in real time in site through its infrared sensor part and signal processing module. |
Fixed Infrared thermometer
|
|
|
GAS DNA PIR550 Non-Contact Portable Infrared thermometer
|
|
The thermometer is a non-contact infrared thermometer. It can measure from -60 to 550 ℃ (-76~1022 ºF) in the distance of 75:1 DS (Distance to Spot) ratio There are many mathematical modes for the Infrared function |
Portable Infrared thermometer
|
|
|
GAS DNA PIR1500 Non-Contact Portable Infrared thermometer
|
|
The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from -35 to 1500 ℃ (-31~2732 ºF) in the distance of 75:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the specific measurement with emissivity. There are many mathematical modes for the Infrared function. |
Portable Infrared thermometer
|
|
|
GAS DNA PIR2400 Non-Contact Portable Infrared thermometer
|
|
The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from 200 to 2400 ℃ (392 to 4352 ºF) in the distance of 100:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the specific measurement with emissivity. There are many mathematical modes for the Infrared function.
[ Specification ]
Item
Non-contact Infrared Scan
function Thermocouple Probe Scan function (K type; a bead wire... |
Portable Infrared thermometer
|
|
|
GAS DNA DI-20 Multi-input indicator
|
|
DI-20 has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm |
Indicator
|
|
|
GAS DNA Airpurge
|
|
Air purge removes dust around infrared thermometer. It can be applicable to IR-20, IR-20-4W, IR-21, IR-40, IR-80, IR-80-H, 6-IRman, 2S-IR-100, 2IGA-IR-100 |
Accessories
|
|
|
GAS DNA Water-cooling jacket
|
|
Water-cooling jacket is to use under the high temperature environment. It makes infrared thermometer cool down and working properly. It can be applicable to IR-40, IR-80, IR-80-H, 2S-IR-100, 2IGA-IR-100 |
Accessories
|
|
|
GAS DNA Water-cooling jacket Bracket
|
|
Bracket is to fix infrared thermometer. |
Accessories
|
|
|
GAS DNA Converter
|
|
Converter is to use to communicate with computer. It can be applicable to IR-21, IR-40, IR-80, IR-80-H, 6-IRman. 2S-IR-100, 2IGA-IR-100 |
Accessories
|
|
|
GW INSTEK GRF-1300
|
|
Features
- Waveform Support :* Sine Wave: 0.1 ~ 3MHz* Square Wave: 0.1 ~ 3MHz* Triangle Wave: 0.1 ~ 3MHz- RF Frequency : 870 ~ 920MHz- AM Modulation & FM Modulation- 5 On/Off Switches and 5 Test Points to Simulate 8 Failure Conditions for Trouble-Shooting Study- USB Interface to Provide Remote Control |
RF Training Systems
|
|
|
GW INSTEK GRF-1300A
|
|
Features
- Baseband Signal : Sine, Triangle, Square wave- Frequency Range: 0.1 ~ 3MHz- RF Frequency : 870 ~ 920MHz- AM & FM Modulation- Mixer & 2.4GHz Bandpass Filter- 5 programmable On/Off Switches and 5 Test Points to Simulate 8 Failure Conditions for Trouble-Shooting Study- USB Interface to Provide Remote Control |
RF Training Systems
|
|
|
GW INSTEK GRF-3300 Series
|
|
Features
* Designed for wireless frequency range applications * Includes a 880MHz Digital PLL and 2.4GHz microstrip line filter circuits* Include these applications of RF Transmitter and Receiver both * Training for the Voice Communication System * Demonstrates the applications and measurements for using spectrum analyzers in communication instruments * Specific RF circuit characteristics & PCB Layout on each module * Training system covering 22 modules, and over... |
RF Training Systems
|
|
|
GW INSTEK AFG-3000 Series
|
|
Features
* Wide frequency range from 1uHz to 80/50MHz* High 200MSa/s sampling rate * 16-bit Amplitude Resolution* Output from any section of 1M-point-long waveforms* 4.3" high resolution LCD display/on-screen help/Impedance switch* Four ways to generate arbitrary waveforms: Front Panel Operation CSV file uploading, Direct Waveform Reconstruction (DWR), ArbitraryWaveform Editing PC Software * USB, RS-232, GPIB interface support |
Arbitrary Function Generators
|
|
|
GW INSTEK AFG-2225
|
|
Features:
* Wide Frequency Ranges From 1μHz to 25MHz (sine/square wave) * 1 μHz Resolution in Full Range * Built-in Standard 120MSa/s, 10bit, 4k Points Arbitrary Waveform for Both Channels* True Dual-Channel Output, CH2 Provides the Same Characteristics as CH1* Couple, Tracking, Phase Operations of Dual Channel are Supported* 1% ~ 99% Adjustable Duty Cycle for Square Waveform * High Resolution and Colored TFT LCD with Friendly User Interface * Multiple Editing methods to... |
Arbitrary Function Generators
|
|
|
GW INSTEK AFG-100/200 Series
|
|
Features
- Frequency range: 1uHz~25MHz- 1uHz frequency resolution - Built-in 120 MSa/s, 10 bit resolution and arbitrary waveform editing function with 4k point memory- Dual channel models support coupling, tracking, and phase functions- Square waveform can adjust the duty cycle from 1% to 99%.- Support various arbitrary waveform editing methods.- Built-in AM/FM/PM/FSK/SUM(AFG-225/225P) modulation, sweep and burst functions- USB interface signal control- AFG-125P/225P provide three DC... |
Arbitrary Function Generators
|
|
|
GW INSTEK AFG-2000/2100 Series
|
|
Features
* 0.1Hz to 5/12/25 MHz with in 0.1Hz Resolution* Sine, Square, Triangular, Noise and Arbitrary Waveform* 20MSa/s Sampling Rate, 10 bit Vertical Resolution and 4k Point Memory for Arbitrary Waveform * 1% ~ 99% adjustable duty cycle for Square Waveform* Waveform Parameter Setting Through Numeric Keypad Entry & Knob Selection* Amplitude, DC Offset and Other Key Setting Information Shown on the 3.5” LCD Screen Simultaneously* AM/FM/FSK Modulation, Sweep, and Frequency Counter... |
Arbitrary Function Generators
|
|
|
GW INSTEK SFG-2100/2000 Series
|
|
Features
*DDS Technique and FPGA Chip Design *Frequency Range : 0.1Hz~4/10MHz *High Frequency Accuracy : ± 20ppm *Frequency Resolution : 100mHz *Low Distortion Sine Wave : -55dBc,0.1Hz~200kHz *Front Panel Setting Save/Recall with 10 Groups of Setting Memories *Built-In 9 Digits,150MHz/High Resolution Counter(SFG-2110 Only)*INT/EXT AM/FM Modulation (SFG-2110 Only)*LIN/LOG Sweep Mode(SFG-2110 Only) |
DDS Function Generators
|
|
|
GW INSTEK SFG-1000 Series
|
|
Features
*DDS Technique and FPGA Chip Design *Frequency Range:0.1Hz~3MHz *High Frequency Accuracy : ± 20ppm *High Frequency Stability : ± 20ppm *Max. Frequency Resolution : 100mHz *Low Distortion Sine Wave : -55dBc,0.1Hz~200kHz *Voltage Display (Only SFG-1013) |
DDS Function Generators
|
|