Kyoritsu

  • Filter
  Name SKU Description Category
Kyoritsu 2413R Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement. • True RMS enables an accurate measurement for distorted waveforms. • Measurement from mA up toAC 1000A • Frequency filter switch to eliminate the effect of the harmonics. • 2 way analogue output terminal:AC current detected by transformer jaws is converted to AC and DC voltage. Output cord model 7073 (option) is... Leakage Clamp Meters
Kyoritsu 8143 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 8215All Clamps demo panel This panel demonstrates the operation of all Kyoritsu AC, AC/DC and Leakage clamp meters including the special open jaw AC/DC clamp meters like KEW FORK 2300R or KEW MATE 2000 series. It features the "actual size" photos of 3 different instruments. However for an effective demonstration, real samples of these instruments should be attached to the panel using a simple anti-theft cable supplied with the panel. This panel generates approx: 15A AC and DC, 30 mA AC of leakage current, 12V AC, 15V DC... Demonstration Panels
Kyoritsu 4300 KEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.)   • 200/2000Ω (2 ranges): auto-ranging. • Warning buzzer triggered at 100Ω or less. • LED lights up when a large earth voltage is detected. • Live circuit warning when 30V or higher voltage is detected. (KEW... Earth Testers
Kyoritsu 5402D Accurate digital readout of tripping time. • Two neon lamps give quick check for correct wiring. • Compact, lightweight and simple to operate. • Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed. RCD Tester
Kyoritsu 6010A Continuity and Insulation Testing • Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live • Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing • Integral overload protection on internal continuity and insulation test circuitry • Autoranging • 500V DC test voltage for insulation tests • 200mA short circuit current on... Multi Function Testers
Kyoritsu 6300 12 kinds of power measurements Voltage (RMS), Current (RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cos θ), frequency , demand measurement, current flowing on the neutral line(Only on 3 phase 4 wire measurement) Regenerative electric power can be measured Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated... Power Meter
Kyoritsu 8112 AC CLAMP ADAPTOR • Model 8112 clamp adaptor is designed to be an AC current/voltage conversion probe capable of measuring AC current from 0.1mA to 120A in conjunction with digital multimeters. Simple to operate, the unit has range switch position at 200mA,2A and 20A. It also features safety design throughout with no exposed metal parts. Sensors, Multi-Trans, Clamp adaptors
Kyoritsu 7061 Applicablemodel   8113   • Output Cords • 1,100mm Test Leads
Kyoritsu 9119 Applicablemodels   5000     5001     5010     5020   • Carrying case [Hard] • 327 (L) × 310 (W) × 120 (D)mm • Up to 3 sensors can be packed into the hard carry case.All the clamp sensors can fit in the case except for the KEW 8123 clamp sensor.(*) Combinations available can be checked here. Case
Kyoritsu 1011 Temperature measurement, selectable for ºC and ºF • 6040 counts with Bar Graph display • MIN/MAX function enables to record min & max value • REL(relative value) function to indicate the measurement variation Digital Multimeters
Kyoritsu 2007A Sleep function to save battery • Data hold function. • Digital display with maximum 4000 counts.   AC Digital Clamp Meters
Kyoritsu 8017 Applicablemodels   4300     7103     7139     7103A     7139A     7149     7150     7149A     7150A     7128     7128A   • Extension prod Clip etc.
Kyoritsu 3001B Compact and lightweight digital Insulation / Continuity Tester. Digital Insulation / Continuity Tester
Kyoritsu 3126 Short-Circuit Current up to 5mA • Wide range measurements from 500V to 5000V and up to 1TΩ • Large digital display with Bar Graph indication and white LED back light • Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR) • Filter function reduces noise interference for obtaining stable measurement • Indication of Output voltage and Discharge voltage • Auto-discharge function and Output voltage warning... High Voltage Insulation Tester
Kyoritsu 2010 High sensitivity, miniature AC/DC clamp meter. • 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current. • Output terminal for recorder connection. AC/DC Digital Clamp Meters
Kyoritsu 8031 Phase Indicator with open phase checker • Phase indicator designed to check the presence of open phase and also the phase sequence by rotating disk and lamps. • Can check a wide range of 3-phase power source from 110V to 600V. Phase Indicator
Kyoritsu 2431 Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges 20mA/200mA/200A. • Rotary switch for easy one finger power-on and range selection. Leakage Clamp Meters
Kyoritsu 4106 Earth Resistance & Resistivity Tester High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range. • Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements. • Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency. • Several sub-results can be shown on the display:... Earth Testers
Kyoritsu 6011A Complies with IEC 61557 • Designed to IP 54 Rating • Live circuit and wiring connection check LED's • Triple ranges insulation tests at 250, 500 and 1000V • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip) • Phase angle selection on RCD ranges • Polarity switch for continuity tests • Auto-null facility for continuity tests • Earth probe for loop impedance testing on extraneous... Multi Function Testers